ATV310H075N4E
درایو 0.75 کیلووات، سه فاز سری ATV310
variable speed drive ATV310, 0.75 kW, 1 hp, 380...460 V, 3 phase, without filter
مشخصات کامل
سری
Easy Altivar 310
range of product
product or component type
Variable speed drive
product or component type
product specific application
Simple machine
product specific application
assembly style
With heat sink
assembly style
device short name
ATV310
device short name
network number of phases
Three phase
network number of phases
[Us] rated supply voltage
380...460 V - 15...10 %
[Us] rated supply voltage
motor power kW
0.75 kW
motor power kW
motor power hp
1 hp
motor power hp
product destination
Asynchronous motors
product destination
quantity per set
Set of 1
quantity per set
EMC filter
Without
EMC filter
supply frequency
50/60 Hz +/- 5 %
supply frequency
communication port protocol
Modbus
communication port protocol
connector type
RJ45 (on front face) for Modbus
connector type
physical interface
2-wire RS 485 for Modbus
physical interface
transmission frame
RTU for Modbus
transmission frame
transmission rate
4800 bit/s
9600 bit/s
19200 bit/s
38400 bit/s
transmission rate
number of addresses
1…247 for Modbus
number of addresses
communication service
Read holding registers (03) 29 words
Write single register (06) 29 words
Write multiple registers (16) 27 words
Read/write multiple registers (23) 4/4 words
Read device identification (43)
communication service
line current
3.1 A
line current
apparent power
2.5 kVA
apparent power
prospective line Isc
5 kA
prospective line Isc
continuous output current
2.3 A at 4 kHz
continuous output current
maximum transient current
3.5 A for 60 s
maximum transient current
power dissipation in W
28.83 W at In
power dissipation in W
speed drive output frequency
0.5…400 Hz
speed drive output frequency
nominal switching frequency
4 kHz
nominal switching frequency
switching frequency
2...12 kHz adjustable
switching frequency
speed range
1…20
speed range
transient overtorque
170…200 % of nominal motor torque depending on drive rating and type of motor
transient overtorque
braking torque
Up to 150 % of nominal motor torque with braking resistor at high inertia
Up to 70 % of nominal motor torque without braking resistor
braking torque
asynchronous motor control profile
Sensorless flux vector control
Quadratic voltage/frequency ratio
Sensorless flux vector control
asynchronous motor control profile
motor slip compensation
Adjustable
Preset in factory
motor slip compensation
output voltage
380...460 V three phase
output voltage
electrical connection
Terminal, clamping capacity: 1.5...2.5 mm² (L1, L2, L3, PA/+, PB, U, V, W)
electrical connection
tightening torque
0.8…1 N.m
tightening torque
insulation
Electrical between power and control
insulation
supply
Internal for reference potentiometer: 5 V (4.75…5.25 V)DC, <10 mA with overload and short-circuit protection
Internal for logic inputs: 24 V (20.4…28.8 V)DC, <100 mA with overload and short-circuit protection
supply
analogue input number
1
analogue input number
analogue input type
Configurable current AI1 0...20 mA 250 Ohm
Configurable voltage AI1 0...10 V 30 kOhm
Configurable voltage AI1 0...5 V 30 kOhm
analogue input type
discrete input number
4
discrete input number
discrete input type
Programmable LI1...LI4 24 V 18...30 V
discrete input type
discrete input logic
Negative logic (sink), > 16 V (state 0), < 10 V (state 1), input impedance 3.5 kOhm
Positive logic (source), 0...< 5 V (state 0), > 11 V (state 1)
discrete input logic
sampling duration
10 ms for analogue input
20 ms, tolerance +/- 1 ms for logic input
sampling duration
linearity error
+/- 0.3 % of maximum value for analogue input
linearity error
analogue output number
1
analogue output number
analogue output type
AO1 software-configurable voltage: 0...10 V, impedance: 470 Ohm, resolution 8 bits
AO1 software-configurable current: 0...20 mA, impedance: 800 Ohm, resolution 8 bits
analogue output type
discrete output number
2
discrete output number
discrete output type
Logic output LO+, LO-
Protected relay output R1A, R1B, R1C 1 C/O
discrete output type
minimum switching current
5 mA at 24 V DC for logic relay
minimum switching current
maximum switching current
2 A at 250 V AC on inductive load cos phi = 0.4 L/R = 7 ms for logic relay
2 A at 30 V DC on inductive load cos phi = 0.4 L/R = 7 ms for logic relay
3 A at 250 V AC on resistive load cos phi = 1 L/R = 0 ms for logic relay
4 A at 30 V DC on resistive load cos phi = 1 L/R = 0 ms for logic relay
maximum switching current
acceleration and deceleration ramps
U
U
S
acceleration and deceleration ramps
braking to standstill
By DC injection, <30 s
braking to standstill
protection type
Line supply overvoltage
Line supply undervoltage
Overcurrent between output phases and earth
Overheating protection
Short-circuit between motor phases
Against input phase loss in three-phase
Thermal motor protection via the drive by continuous calculation of I²t
protection type
frequency resolution
Analog input: converter A/D, 10 bits
Display unit: 0.1 Hz
frequency resolution
time constant
20 ms +/- 1 ms for reference change
time constant
operating position
Vertical +/- 10 degree
operating position
height
143 mm
height
width
72 mm
width
depth
140 mm
depth
net weight
0.8 kg
net weight
electromagnetic compatibility
Electrical fast transient/burst immunity test - test level: level 4 conforming to EN/IEC 61000-4-4
Electrostatic discharge immunity test - test level: level 3 conforming to EN/IEC 61000-4-2
Immunity to conducted disturbances - test level: level 3 conforming to EN/IEC 61000-4-6
Radiated radio-frequency electromagnetic field immunity test - test level: level 3 conforming to EN/IEC 61000-4-3
Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11
Surge immunity test - test level: level 3 conforming to EN/IEC 61000-4-5
electromagnetic compatibility
standards
EN/IEC 61800-5-1
EN/IEC 61800-5-1
standards
IP degree of protection
IP20 without blanking plate on upper part
IP40 top
IP degree of protection
pollution degree
2 conforming to EN/IEC 61800-5-1
pollution degree
environmental characteristic
Dust pollution resistance class 3S2 conforming to EN/IEC 60721-3-3
Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
environmental characteristic
shock resistance
15 gn conforming to EN/IEC 60068-2-27 for 11 ms
shock resistance
relative humidity
5…95 % without condensation conforming to IEC 60068-2-3
5…95 % without dripping water conforming to IEC 60068-2-3
relative humidity
ambient air temperature for storage
-25…70 °C
ambient air temperature for storage
ambient air temperature for operation
-10…55 °C without derating
55…60 °C protective cover from the top of the drive removed with current derating 2.2 % per °C
ambient air temperature for operation
operating altitude
<= 1000 m without derating
operating altitude
Unit Type of Package 1
PCE
Unit Type of Package 1
Number of Units in Package 1
1
Number of Units in Package 1
Package 1 Weight
1.05 kg
Package 1 Weight
Package 1 Height
13 cm
Package 1 Height
Package 1 width
18.5 cm
Package 1 width
Package 1 Length
19 cm
Package 1 Length
Unit Type of Package 2
S06
Unit Type of Package 2
Number of Units in Package 2
39
Number of Units in Package 2
Package 2 Weight
50.95 kg
Package 2 Weight
Package 2 Height
74 cm
Package 2 Height
Package 2 width
60 cm
Package 2 width
Package 2 Length
80 cm
Package 2 Length