GV3ME80
کليد حرارتی 56 تا 80 آمپر
Motor circuit breaker, TeSys GV3, 3P, 56-80 A, thermal magnetic, screw clamp terminals
مشخصات کامل
گروه
TeSys Deca
range
سری
TeSys GV3
range of product
device short name
GV3ME
device short name
نام محصول
TeSys GV3
product name
product or component type
Motor circuit breaker
product or component type
device application
Motor protection
device application
trip unit technology
Thermal-magnetic
trip unit technology
poles description
3P
poles description
network type
AC
network type
utilisation category
AC-3 conforming to IEC 60947-4-1
Category A conforming to IEC 60947-2
utilisation category
network frequency
50/60 Hz conforming to IEC 60947-4-1
network frequency
fixing mode
35 mm symmetrical DIN rail: clipped
Panel: screwed (with 2 x M4 screws)
fixing mode
operating position
Any position
operating position
motor power kW
37 kW at 400/415 V AC 50/60 Hz
55 kW at 690 V AC 50/60 Hz
45 kW at 500 V AC 50/60 Hz
motor power kW
breaking capacity
100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
4 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
2 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
breaking capacity
[Ics] rated service short-circuit breaking capacity
100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
60 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity
control type
Push-button
control type
[In] rated current
80 A
[In] rated current
thermal protection adjustment range
56…80 A
thermal protection adjustment range
magnetic tripping current
1040 A
magnetic tripping current
[Ue] rated operational voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage
[Ui] rated insulation voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage
[Ith] conventional free air thermal current
80 A conforming to IEC 60947-4-1
[Ith] conventional free air thermal current
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage
power dissipation per pole
8 W
power dissipation per pole
mechanical durability
30000 cycles
mechanical durability
electrical durability
30000 cycles for AC-3 at 440 V
electrical durability
maximum operating rate
25 cyc/h
maximum operating rate
rated duty
Continuous conforming to IEC 60947-4-1
rated duty
tightening torque
5 N.m on screw clamp terminals
tightening torque
phase failure sensitivity
Yes conforming to IEC 60947-4-1
phase failure sensitivity
height
120 mm
height
width
61.2 mm
width
depth
113 mm
depth
net weight
0.7 kg
net weight
standards
EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
standards
product certifications
CCC
EAC
ABS
LROS (Lloyds register of shipping)
DNV-GL
BV
product certifications
climatic withstand
conforming to IACS E10
climatic withstand
IK degree of protection
IK04
IK degree of protection
IP degree of protection
IP20 conforming to IEC 60529
IP degree of protection
ambient air temperature for storage
-40…80 °C
ambient air temperature for storage
fire resistance
960 °C conforming to IEC 60695-2-1
fire resistance
operating altitude
3000 m
operating altitude
ambient air temperature for operation
-20…60 °C
ambient air temperature for operation
Unit Type of Package 1
PCE
Unit Type of Package 1
Number of Units in Package 1
1
Number of Units in Package 1
Package 1 Weight
721.0 g
Package 1 Weight
Package 1 Height
7 cm
Package 1 Height
Package 1 width
12.5 cm
Package 1 width
Package 1 Length
13.3 cm
Package 1 Length
Warranty
18 months
Warranty