کنتاکتور 115 آمپر بوبین 24V DC
×
کنتاکتور 115 آمپر بوبین 24V DC

LC1D115BD

کنتاکتور 115 آمپر بوبین 24V DC

TeSys Deca contactor, 3P(3NO), AC-3, 440V, 115A, 24V DC standard coil

مشخصات کامل
گروه
TeSys
range
نام محصول
TeSys D TeSys Deca
product name
product or component type
Contactor
product or component type
device short name
LC1D
device short name
contactor application
Resistive load Motor control
contactor application
utilisation category
AC-4 AC-1 AC-3
utilisation category
poles description
3P
poles description
power pole contact composition
3 NO
power pole contact composition
[Ue] rated operational voltage
Power circuit: <= 1000 V AC 25...400 Hz Power circuit: <= 300 V DC
[Ue] rated operational voltage
[Ie] rated operational current
200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 115 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
[Ie] rated operational current
motor power kW
30 kW at 220...230 V AC 50/60 Hz (AC-3) 55 kW at 380...400 V AC 50/60 Hz (AC-3) 59 kW at 415...440 V AC 50/60 Hz (AC-3) 75 kW at 500 V AC 50/60 Hz (AC-3) 80 kW at 660...690 V AC 50/60 Hz (AC-3) 65 kW at 1000 V AC 50/60 Hz (AC-3) 18.5 kW at 400 V AC 50/60 Hz (AC-4)
motor power kW
motor power HP (UL / CSA)
30 hp at 200/208 V AC 50/60 Hz for 3 phases motors 40 hp at 230/240 V AC 50/60 Hz for 3 phases motors 75 hp at 460/480 V AC 50/60 Hz for 3 phases motors 100 hp at 575/600 V AC 50/60 Hz for 3 phases motors
motor power HP (UL / CSA)
control circuit type
DC standard
control circuit type
[Uc] control circuit voltage
24 V DC
[Uc] control circuit voltage
auxiliary contact composition
1 NO + 1 NC
auxiliary contact composition
[Uimp] rated impulse withstand voltage
8 kV conforming to IEC 60947
[Uimp] rated impulse withstand voltage
overvoltage category
III
overvoltage category
[Ith] conventional free air thermal current
200 A (at 60 °C) for power circuit
[Ith] conventional free air thermal current
Irms rated making capacity
1260 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1
Irms rated making capacity
rated breaking capacity
1100 A at 440 V for power circuit conforming to IEC 60947
rated breaking capacity
[Icw] rated short-time withstand current
250 A 40 °C - 10 min for power circuit 550 A 40 °C - 1 min for power circuit 950 A 40 °C - 10 s for power circuit 1100 A 40 °C - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit
[Icw] rated short-time withstand current
associated fuse rating
250 A gG at <= 690 V coordination type 1 for power circuit 200 A gG at <= 690 V coordination type 2 for power circuit 10 A gG for signalling circuit
associated fuse rating
average impedance
0.6 mOhm - Ith 200 A 50 Hz for power circuit
average impedance
[Ui] rated insulation voltage
Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified
[Ui] rated insulation voltage
electrical durability
0.8 Mcycles 200 A AC-1 at Ue <= 440 V 0.95 Mcycles 115 A AC-3 at Ue <= 440 V
electrical durability
power dissipation per pole
24 W AC-1 7.9 W AC-3
power dissipation per pole
Front cover
With
Front cover
mounting support
Plate Rail
mounting support
standards
CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
standards
product certifications
CCC UL BV CSA GL GOST DNV LROS (Lloyds register of shipping) RINA UKCA
product certifications
connections - terminals
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end Power circuit: connector 1 cable(s) 10…120 mm²flexible without cable end Power circuit: connector 2 cable(s) 10…50 mm²flexible without cable end Power circuit: connector 1 cable(s) 10…120 mm²flexible with cable end Power circuit: connector 2 cable(s) 10…50 mm²flexible with cable end Power circuit: connector 1 cable(s) 10…120 mm²solid without cable end Power circuit: connector 2 cable(s) 10…50 mm²solid without cable end
connections - terminals
tightening torque
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 12 N.m - on connector hexagonal screw head 4 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
tightening torque
operating time
20...35 ms closing 40...75 ms opening
operating time
safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
safety reliability level
mechanical durability
8 Mcycles
mechanical durability
maximum operating rate
1200 cyc/h 60 °C
maximum operating rate
coil technology
With integral suppression device
coil technology
control circuit voltage limits
0.75...1.2 Uc (-40…55 °C):operational DC 0.15...0.4 Uc (-40…70 °C):drop-out DC 1...1.2 Uc (55…70 °C):operational DC
control circuit voltage limits
time constant
25 ms
time constant
inrush power in W
270…365 W (at 20 °C)
inrush power in W
hold-in power consumption in W
2.4…5.1 W at 20 °C
hold-in power consumption in W
auxiliary contacts type
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1
auxiliary contacts type
signalling circuit frequency
25...400 Hz
signalling circuit frequency
minimum switching current
5 mA for signalling circuit
minimum switching current
minimum switching voltage
17 V for signalling circuit
minimum switching voltage
non-overlap time
1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
non-overlap time
insulation resistance
> 10 MOhm for signalling circuit
insulation resistance
IP degree of protection
IP20 front face conforming to IEC 60529
IP degree of protection
climatic withstand
conforming to IACS E10
climatic withstand
protective treatment
TH conforming to IEC 60068-2-30
protective treatment
pollution degree
3
pollution degree
ambient air temperature for operation
-40…60 °C 60…70 °C with derating
ambient air temperature for operation
ambient air temperature for storage
-60…80 °C
ambient air temperature for storage
operating altitude
0...3000 m
operating altitude
fire resistance
850 °C conforming to IEC 60695-2-1
fire resistance
mechanical robustness
Vibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Shocks contactor open: 6 Gn for 11 ms
mechanical robustness
height
158 mm
height
width
120 mm
width
depth
136 mm
depth
net weight
2.5 kg
net weight
Unit Type of Package 1
PCE
Unit Type of Package 1
Number of Units in Package 1
1
Number of Units in Package 1
Package 1 Weight
2.478 kg
Package 1 Weight
Package 1 Height
20 cm
Package 1 Height
Package 1 width
22 cm
Package 1 width
Package 1 Length
23 cm
Package 1 Length
Unit Type of Package 2
P06
Unit Type of Package 2
Number of Units in Package 2
27
Number of Units in Package 2
Package 2 Weight
79.798 kg
Package 2 Weight
Package 2 Height
75 cm
Package 2 Height
Package 2 width
80 cm
Package 2 width
Package 2 Length
60 cm
Package 2 Length
Warranty
18 months
Warranty