LC1D150P7
کنتاکتور 150 آمپر بوبین 230V AC
TeSys Deca contactor, 3P(3NO), AC-3, 440V, 150 A, 230V AC 50/60 Hz coil
مشخصات کامل
گروه
TeSys
range
نام محصول
TeSys D
TeSys Deca
product name
product or component type
Contactor
product or component type
device short name
LC1D
device short name
contactor application
Motor control
Resistive load
contactor application
utilisation category
AC-3
AC-4
AC-1
utilisation category
poles description
3P
poles description
power pole contact composition
3 NO
power pole contact composition
[Ue] rated operational voltage
Power circuit: <= 1000 V AC 25...400 Hz
Power circuit: <= 300 V DC
[Ue] rated operational voltage
[Ie] rated operational current
200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
150 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
[Ie] rated operational current
motor power kW
40 kW at 220...230 V AC 50/60 Hz (AC-3)
75 kW at 380...400 V AC 50/60 Hz (AC-3)
80 kW at 415...440 V AC 50/60 Hz (AC-3)
90 kW at 500 V AC 50/60 Hz (AC-3)
100 kW at 660...690 V AC 50/60 Hz (AC-3)
75 kW at 1000 V AC 50/60 Hz (AC-3)
22 kW at 400 V AC 50/60 Hz (AC-4)
motor power kW
motor power HP (UL / CSA)
40 hp at 200/208 V AC 50/60 Hz for 3 phases motors
50 hp at 230/240 V AC 50/60 Hz for 3 phases motors
100 hp at 460/480 V AC 50/60 Hz for 3 phases motors
125 hp at 575/600 V AC 50/60 Hz for 3 phases motors
motor power HP (UL / CSA)
control circuit type
AC at 50/60 Hz
control circuit type
[Uc] control circuit voltage
230 V AC 50/60 Hz
[Uc] control circuit voltage
auxiliary contact composition
1 NO + 1 NC
auxiliary contact composition
[Uimp] rated impulse withstand voltage
8 kV conforming to IEC 60947
[Uimp] rated impulse withstand voltage
overvoltage category
III
overvoltage category
[Ith] conventional free air thermal current
200 A (at 60 °C) for power circuit
[Ith] conventional free air thermal current
Irms rated making capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1660 A at 440 V for power circuit conforming to IEC 60947
Irms rated making capacity
rated breaking capacity
1400 A at 440 V for power circuit conforming to IEC 60947
rated breaking capacity
[Icw] rated short-time withstand current
250 A 40 °C - 10 min for power circuit
580 A 40 °C - 1 min for power circuit
1200 A 40 °C - 10 s for power circuit
1400 A 40 °C - 1 s for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
[Icw] rated short-time withstand current
associated fuse rating
10 A gG for signalling circuit conforming to IEC 60947-5-1
315 A gG at <= 690 V coordination type 1 for power circuit
250 A gG at <= 690 V coordination type 2 for power circuit
associated fuse rating
average impedance
0.6 mOhm - Ith 200 A 50 Hz for power circuit
average impedance
[Ui] rated insulation voltage
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Power circuit: 1000 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
[Ui] rated insulation voltage
electrical durability
0.85 Mcycles 150 A AC-3 at Ue <= 440 V
1 Mcycles 200 A AC-1 at Ue <= 440 V
electrical durability
power dissipation per pole
24 W AC-1
13.5 W AC-3
power dissipation per pole
Front cover
With
Front cover
mounting support
Plate
Rail
mounting support
standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
standards
product certifications
DNV
GOST
RINA
UL
CSA
LROS (Lloyds register of shipping)
GL
CCC
BV
UKCA
product certifications
connections - terminals
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²solid without cable end
Power circuit: connector 1 cable(s) 10…120 mm²flexible without cable end
Power circuit: connector 2 cable(s) 10…50 mm²flexible without cable end
Power circuit: connector 1 cable(s) 10…120 mm²flexible with cable end
Power circuit: connector 2 cable(s) 10…50 mm²flexible with cable end
Power circuit: connector 1 cable(s) 10…120 mm²solid without cable end
Power circuit: connector 2 cable(s) 10…50 mm²solid without cable end
connections - terminals
tightening torque
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2
Power circuit: 12 N.m - on connector hexagonal screw head 4 mm
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
tightening torque
operating time
20...35 ms closing
40...75 ms opening
operating time
safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
safety reliability level
mechanical durability
8 Mcycles
mechanical durability
maximum operating rate
1200 cyc/h 60 °C
maximum operating rate
coil technology
Built-in bidirectional peak limiting diode suppressor
coil technology
control circuit voltage limits
0.3...0.5 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8...1.15 Uc (-40…55 °C):operational AC 50/60 Hz
1...1.15 Uc (55…70 °C):operational AC 50/60 Hz
control circuit voltage limits
inrush power in VA
280…350 VA 60 Hz cos phi 0.9 (at 20 °C)
280…350 VA 50 Hz cos phi 0.9 (at 20 °C)
inrush power in VA
hold-in power consumption in VA
2…18 VA 60 Hz cos phi 0.9 (at 20 °C)
2…18 VA 50 Hz cos phi 0.9 (at 20 °C)
hold-in power consumption in VA
heat dissipation
3…4.5 W at 50/60 Hz
heat dissipation
auxiliary contacts type
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
auxiliary contacts type
signalling circuit frequency
25...400 Hz
signalling circuit frequency
minimum switching current
5 mA for signalling circuit
minimum switching current
minimum switching voltage
17 V for signalling circuit
minimum switching voltage
non-overlap time
1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
non-overlap time
insulation resistance
> 10 MOhm for signalling circuit
insulation resistance
IP degree of protection
IP20 front face conforming to IEC 60529
IP degree of protection
climatic withstand
conforming to IACS E10
climatic withstand
protective treatment
TH conforming to IEC 60068-2-30
protective treatment
pollution degree
3
pollution degree
ambient air temperature for operation
-40…60 °C
60…70 °C with derating
ambient air temperature for operation
ambient air temperature for storage
-60…80 °C
ambient air temperature for storage
operating altitude
0...3000 m
operating altitude
fire resistance
850 °C conforming to IEC 60695-2-1
fire resistance
mechanical robustness
Vibrations contactor open: 2 Gn, 5...300 Hz
Vibrations contactor closed: 4 Gn, 5...300 Hz
Shocks contactor closed: 15 Gn for 11 ms
Shocks contactor open: 6 Gn for 11 ms
mechanical robustness
height
158 mm
height
width
120 mm
width
depth
136 mm
depth
net weight
2.5 kg
net weight
Unit Type of Package 1
PCE
Unit Type of Package 1
Number of Units in Package 1
1
Number of Units in Package 1
Package 1 Weight
2.491 kg
Package 1 Weight
Package 1 Height
17 cm
Package 1 Height
Package 1 width
18.5 cm
Package 1 width
Package 1 Length
20.5 cm
Package 1 Length
Unit Type of Package 2
P06
Unit Type of Package 2
Number of Units in Package 2
27
Number of Units in Package 2
Package 2 Weight
75.257 kg
Package 2 Weight
Package 2 Height
75 cm
Package 2 Height
Package 2 width
80 cm
Package 2 width
Package 2 Length
60 cm
Package 2 Length
Warranty
18 months
Warranty